Imports - PM Import Information
Field | Value | Type/Size | Required for create new | Required for Update | Update Allowed |
---|---|---|---|---|---|
Asset Facility | Must be an existing facility | int(5) | |||
Asset Number | Must Match and existing asset in that facility | char(8) | |||
PM Code | A0 thru Z9 | char(1)Int(1) | |||
Include PM Code | A0 thru Z9 | char(1)Int(1) | |||
Major VMRS | Must match an existing code | int(3) | |||
Intermediate VMRS | Must match an existing code | int(3) | |||
Minor VMRS | Must match an existing code | int(3) | |||
Description |
| char(50) | |||
Template WO Facility |
| int(5) | |||
Template WO Number |
| char(7) | |||
Part Kit Facility |
| int(5) | |||
Part Kit Number |
| char(25) | |||
PM Enabled | Y = PM Enabled (Default) N = PM Not Enabled | char(1) | |||
One Time PM | Y = One Time Use PM N = Recurring PM (Default) | char(1) | |||
Inspection |
| char(15) | |||
Primary Meter | D = Days (Default) | char(1) | |||
Lock Days/Months | P = interval is Months (uses CCYYMM from date posted) M = locked interval is Months (ignores date posted) D = locked interval is Days Space = Days meter is NOT locked (Default) | char(1) | |||
Interval Days |
| int(6) | |||
Last Done Date |
| date | |||
Last Done Lock Date |
| date | |||
Lock Meter | Y = Meter interval locked N = Meter interval is NOT locked If not set, set to N | char(1) | |||
Interval Meter |
| int(6) | |||
Last Done Work Meter |
| decimal(8, 1) | |||
Last Done Life Meter |
| int(8) | |||
Last Done Lock Meter |
| int(8) | |||
Interval Gallons |
| int(6) | |||
Last Done Gallons |
| int(8) | |||
Interval Alt Meter 1 | Only valid if the alternate meter is in use | int(6) | |||
Last Done Alt Meter 1 | Only valid if the alternate meter is in use | int(6) | |||
Interval Alt Meter 2 | Only valid if the alternate meter is in use | int(6) | |||
Last Done Alt Meter 2 | Only valid if the alternate meter is in use | int(6) | |||
Interval Alt Meter 3 | Only valid if the alternate meter is in use | int(6) | |||
Last Done Alt Meter 3 | Only valid if the alternate meter is in use | int(6) | |||
Interval Alt Meter 4 | Only valid if the alternate meter is in use | int(6) | |||
Last Done Alt Meter 4 | Only valid if the alternate meter is in use | int(6) | |||
Current WO Facility | Must match existing facility | int(5) | |||
Current WO Number | Must Match existing WO. If filled out, then we should mark PM as scheduled | char(7) | |||
Current WO Line | Must match an existing line on the WO | int(2) | |||
Last WO Facility |
| int(5) | |||
Last WO Number |
| char(7) | |||
Last WO Line |
| int2) | |||
Previous WO Facility |
| int(5) | |||
Previous WO Number |
| char(7) | |||
Previous WO Line |
| int(2) | |||
Sleep Mode Enabled | Y = Sleep enabled N = Sleep disabled | char(1) | |||
Sleep Date |
| date | |||
Days Sleep |
| int(4) | |||
PM is Warranty | Y = PM is Warranty N = PM Not Warranty (Default) | char(1) | |||
Warranty Major VMRS |
| int(3) | |||
Warranty Intermediate VMRS |
| int(3) | |||
Warranty Minor VMRS |
| int(3) |